UV-VIS Spectrophotometer
Advanced UV-Vis Spectrophotometer with 11-inch color touchscreen, photometric, quantitative, kinetic...
View DetailsAtomic Absorption Spectrophotometer (AAS): It is an analytical instrument used to measure the concentration of metals in a sample by measuring the absorption of light by free atoms.
| Models | AA 7804 | AA 7808 | AA 7818 | AA 7828 | ||||
| Optical System | Single Beam | Double Beam | ||||||
| Monochromator | Czerny-Turner type, focal lengths at 350mm | |||||||
| Grating | Holographic diffraction with 1800 lines/mm | |||||||
| Wavelength Range | 190-900 nm | |||||||
| Slits | Automated slit selection 0.1, 0.2, 0.4, 0.7, 1.4, 2.0 nm | |||||||
| Wavelength Repeatability | ±0.1nm | ±0.1 nm | ±0.05 nm | ±0.05 nm | ||||
| Wavelength Accuracy | ±0.3 nm | ±0.2 nm | ±0.15 nm | ±0.15 nm | ||||
| Lamp | Automated 4-lamp | Automated 8-lamp turret | ||||||
| turret | ||||||||
| Reading Mode | T, A, C | |||||||
| Photometric Range | 0-125%, -0.1-3.00A | |||||||
| Static Baseline Drift (Cu) | ≤0.004A/30 min | ≤0.003A/30 min | ≤0.002A/30 min | ≤0.002A/30 min | ||||
| Dynamic Baseline Drift (Cu) | ≤0.006A/15 min | ≤0.005A/15 min | ≤0.004A/15 min | ≤0.004A/15 min | ||||
| Background Correction | Deuterium (D2) Background Correction | Deuterium (D2) Background Correction and | ||||||
| Self-absorption Background Correction | ||||||||
| Models | AA 7804 | AA 7808 | AA 7818 | AA 7828 | ||||
| Flame | Characteristic Concentration | ≤0.04ug/ml | ≤0.035ug/ml | ≤0.02ug/ml | ≤0.02ug/ml | |||
| Detection Limit (Cu) | ≤0.008ug/ml | ≤0.006ug/ml | ≤0.004ug/ml | ≤0.004ug/ml | ||||
| Repeatability (Cu) | RSD≤1% | RSD≤0.6% | RSD≤0.5% | RSD≤0.5% | ||||
| Acetylene Flow Control | Auto 12-Level | |||||||
| Air Assist Control | Auto 4-Level | |||||||
| Ignition Method | PC control | |||||||
| Detector | Wide range UV sensitive photomultiplier tube | |||||||
| Burner Head | Titanium 100mm burner for air/acetylene operation | |||||||
| Nebulizer | High efficiency glass nebulizer | |||||||
| Spray Chamber | Corrosion resistant material spray chamber | |||||||
| Safety Protection | Automatically cut off gas in case of low pressure, power failure, flame out, or burner mismatched | |||||||
Graphite Furnace
| Characteristic Amount | Cd≤0.9pg, Cu≤20pg | Cd≤0.6pg, Cu≤20pg | Cd≤0.5pg, Cu≤20pg | ||||
| Detection Limit (Cu) | Cd≤1.5pg, Cu≤25pg | Cd≤1.0pg, Cu≤25pg | Cd≤0.8pg, Cu≤25pg | |||||
| Repeatability (Cu) | RSD≤4% | RSD≤3% | RSD≤2.5% | |||||
| Heating range of graphite furnace | Room temperature-3000℃ | |||||||
| High power heating range | 1500-3000℃ | |||||||
| Slope and holding time | 1-255s | |||||||
| Heating rate | Maximum heating rate 2000℃/s | |||||||
| Atomization heating mode | Light-controlled heating, Time-controlled heating, General heating | |||||||
| Protective gas flow outside pipe | 1 L/min | |||||||
| Protective gas flow inside pipe | 4-speed adjustable (0, 50, 200, 250/min flow) | |||||||
| Safety Protection | Cooling water flow, Protective gas pressure, Furnace body temperature, Power supply temperature, Graphite furnace installation alarm | |||||||
| Auto Sampler | Optional | |||||||
| Data Processing | Measuring method | Flame method, Graphite furnace method, Hydride generation-Atomic absorption method, Flame emission method | ||||||
| Concentration calculation method | Standard curve method (6 linear/non-linear fitting methods), Standard addition method, Interpolation method | |||||||
| Repeat measurement times | 1-30 times, Calculate and give the average value of absorbance/concentration, standard deviation and relative standard deviation | |||||||
| Report printing | Parameter printing, Data result printing | |||||||
| Dimensions/ Weight | 850 x 650 x 550 mm/95kg | |||||||
| Ambient Temp. | 10 ~ 35 °C | |||||||
| Ambient Humidity | ≦85 % | |||||||
| Power | 110/220V, 50/60Hz | |||||||