e-mail: sales@gennextlab.com
  • Language: English
  • +(91)-(11)-49874025
  • (+91)-9310216788, 9310255506, 9310231746

Home // Product // Portable Dedicated Dissolved Oxygen Meter //HQ1130

HQ1130


HQ1130


 

Specification

  • Backlight: Yes
  • Barometric Pressure Measurement: Automatic compensation of DO when using an LDO or LBOD probe
  • Cable Length: 1 m
  • Calibration Intervals/Alerts/Reminder: Off, selectable from 2 hours to 7 days
  • Certifications: CE, FCC, ISED, RCM, KC, ETL Verified: US DOE/ NRCan Energy Efficiency, RoHS
  • Data Export: USB connection to PC or USB storage device
  • (limited to the storage device capacity).
  • Data Memory: 5000 data points
  • Data Storage: Automatic in Press to Read Mode and Interval Mode. Manual in Continuous Read Mode.
  • Dimensions (H x W x D): 63 mm x 97 mm x 220 mm
  • Display: Up to 3 parameters at a time, dependent on HQ model
  • Display Type: 536x336 Mono-TFT
  • DO Measurement Range: 0.1 - 20.0 mg/L (ppm), 1 - 200% saturation
  • DO Resolution: 0.1
  • Enclosure Rating: IP67 (with battery compartment installed)
  • GLP Features: Date; Time; Sample ID; Operator ID, Calibration
  • Inputs: 1
  • Instrument: Portable
  • Languages: English, Chinese - Simplified, Spanish, French, German, Italian, Japanese, Turkish, Dutch, Portuguese (PT & BR), Korean, Danish, Swedish, Polish, Norwegian, Hungarian, Greek, Finnish, Czech, Romanian, Croatian, Bulgarian, Slovak, Lithuanian, Estonian, Slovenian, Russian
  • Lock Function: Continuous / Auto-stabilisation ("press to read")  At Interval
  • Measurement method: Probe specific programmed method settings
  • Model: HQ1130 DO/1 Channel
  • mV Measurement at Stable Reading: No
  • mV Measurement Range: No
  • Operating Error Messages: Clear text error messages displayed
  • Operating Humidity: 90% (non-condensing)
  • Operating Interface: Soft Touch Keypad
  • Operating Temperature: 0 - 60 °C
  • Parameter: Dissolved Oxygen
  • Power supply: Rechargeable lithium-ion battery 18650 (internal) Class II, USB power adapter: 100 - 240 VAC, 50/60 Hz input; 5 VDC at 2 A USB power adapter output (external)
  • Probes included: LDO10101
  • Probe Type: Intellical Standard Laboratory or Rugged Field
  • Protection Class: IEC Class III (SELV (Separated/Safety Extra- Low Voltage) powered); external
  • Sensor A: LDO10101
  • Sensor B: None
  • Sensor C: None
  • Storage conditions: -20 - 60 °C, max. 90% relative humidity (non- condensing)
  • Temperature Compensation: Automatic Temperature compensation for pH
  • Temperature Measurement: °C or °F
  • Temperature Resolution: 0.1 °C
  • Type of measurement: Field Measurements
  • Weight: 519 g (Meter only)