9184sc Free Chlorine (AFC) Amperometric Sensor

Online Analyzer

9184sc Free Chlorine (AFC) Amperometric Sensor

The low minimum detection limit and wide measurement range of the Hach 9184 sc Amperometric Free Chlorine Sensor makes it ideal for efficient residual chlorine monitoring. Continuously measures hypochlorous acid (HOCl).

Specifications

Accuracy:2 % or ±10 ppb TFC, whichever is greater at pH <7.5

Accuracy 2:2 % or ±10 ppb HOCl, whichever is greater at pH <8

Calibration Interval:2 months

Calibration Method:Zero Calibration: electrically (automatic) or with de-chlorinated water
Calibration: Comparison of lab method with
process sample
pH Calibration: Single- or two-point using standards
or comparison of lab method with
process sample

Description :9184sc Hypochlorous Acid Chlorine Amperometric Sensor

Enclosure Rating:IP66 / NEMA 4X

Flow:0.25 L/h (200 - 250 mL/min) auto--regulated by flow through cell

Interferences:No interference from chloramines.
Chlorine dioxide and ozone interfere with
measurement.

Lower Limit of Detection (LOD):0.005 mg/L HOCl

Maintenance Interval:6 months Measurement Cell: for membrane and electrolyte, typical

Maintenance Interval 2:1 1.5 pH Cell: typical

Measuring Interval:Continuous

Measuring Principle:Amperometric/Membrane (electrode,
membrane, electrolyte)

Mounting:Flat, vertical surface (panel, stand, etc.)

Operating Temperature Range:0 - 45 °C

Parameter:Hypochlorous Acid Only Chlorine

pH Range:4 - 8, acidification unit available for pH > 8

Pressure Range:0.1 - 2 bar in flow cell

Range:0 - 20 mg/L hypochlorous acid HOCl

Relative Humidity:0 - 90 % non-condensing

Response time:90 % in less than 90 seconds

Sample Input:0.25 " outer diameter

Sample Output:0.5 " inner diameter

Sample Temperature:2 - 45 °C

Standard deviation:0.7 %

Storage conditions:-20 - 60 °C

Temperature Compensation:Automatic over sample temperature range

 Automatic over sample temperature range

Features

Low Minimum Detection Limit for Efficient Residual Chlorine Monitoring

The Hach 9184sc sensor has a minimum detection limit of 5 ppb or 0.005 mg/L hypochlorous acid in the form of HOCl.

Wide Measurement Range

The 9184sc sensor is particularly useful for drinking water distribution monitoring, chlorination applications, demineralizer systems, wastewater, or cooling water processes due to its 0 - 20 ppm measurement range.

Continuous Chlorine Measurement

Measurements are made continuously by the sensor and reported to the controller

Compatible with Hach's "Plug and Play" Digital Controllers

The 9184sc Analyzer is designed to be used with all Hach sc digital controllers. Set up is fast and easy, and the system is compatible with the full line of Hach digital sensors.

Integral temperature sensor provides more accurate readings