SC4500 Controller, Prognosys, 5x mA Output, 2 analog Conductivity, 100-240 VAC, without power cord

Online Analyzer

SC4500 Controller, Prognosys, 5x mA Output, 2 analog Conductivity, 100-240 VAC, without power cord

Technologies are advancing rapidly, providing new levels of convenience, accuracy, and efficiency. Which is exactly why the SC4500 Controller from HachⓇ is designed to integrate easily into your current system while allowing you to upgrade as your capabilities advance, without having to replace inventory. With a wide range of analog and digital connectivity options and the availability of intelligent instrument and data management features, the SC4500 unlocks the future, today.

Specifications

Altitude:3000 m maximum

Analog Output Functional Mode:Linear, PID

Communication (optional):Analog:
Five 0 - 20 mA or 4 - 20 mA analog outputs on each analog output module
Up to two analog Input modules (0 - 20 mA or 4 - 20 mA). Each input module replaces a digital sensor input.

Digital:
Profibus DPV1 module
Modbus TCP
Modbus RS
Profinet IO module
Ethernet IP module
HART module

Compatible Instruments:Compatible Sensors and Analysers / Software Version (Release Year)
Amtax sc / V2.30 (2018) or higher
A-ISE sc / V1.02 or higher
AN-ISE sc / V1.08 (2013) or higher
N-ISE sc / V1.02 or higher
Nitratax clear sc, Nitratax eco sc, Nitratax plus sc / V3.13 (2013) or higher
NT3100sc/NT3200sc
Phosphax sc / V2.30 (2018) or higher
Phosphax sc LR/MR/HR / V1.01 (2018) or higher
TSS sc / V41.73 (2013) or higher
Solitax sc / V2.20 (2013) or higher
TU5300sc, TU5400sc / V1.34 (2017) or higher
SS7 sc (in Bypass) / V1.01 (2006) or higher
Ultraturb sc / V3.06 (2017) or higher
1720E / V2.10 (2006) or higher
Sonatax sc / V1.15 (2016) or higher
CL17sc / V2.7 (2019) or higher
CL10sc / V1.14 (2013) or higher
9184sc, 9185sc, 9187sc* / V2.03 (2013) or higher
Uvas plus sc / V3.01 (2017) or higher
LDO 2 sc* / V1.22 (2013) or higher
3798sc* / V2.03 (2013) or higher
3700sc + Inductive Conductive Digital 6120800 / V3.00 (2017) or higher
3422sc + Contacting Conductive Digital 6120700 / V3.00 or higher
3700 analog + Conductivity Module LXZ525.99.D0004
3400 analog + Conductivity Module LXZ525.99.D0004
pHD sc*, pHD-S sc / V3.10 (2016) or higher
1200-S sc* / V2.04 (2013) or higher
pHD analog + Digital Gateway 6120500 / V3.00 (2017) or higher
pHD analog + pH/ORP Module LXZ525.99.D0003
RC and PC analog sensor + Digital Gateway for conventional analog pH and ORP sensors 6120600 / V3.00 (2017) or higher
RC and PC analog + pH/ORP Module LXZ525.99.D0003
8362sc* / V3.00 (2017) or higher
Polymetron pH/ORP analog + Ultrapure pH/ORP Module LXZ525.99.D0007
Polymetron Conductivity analog + Ultrapure Conductivity Module LXZ525.99.D0006
GS1440 and GS2440EX Sensors H₂S
FP360 sc / V1 or higher

*Hardware Version1 of instrument is not supported

Compatible network technologies:GSM 3G/4G (e.g. AT&T, T-Mobile, Rogers, Vodafone etc.)
CDMA (e.g. Verizon)

Compliance Certifications:CE. ETL certified to UL and CSA safety standards (with all sensor types), FCC, ISED, KC, RCM, EAC, UKCA, SABS, C م (Morocco)

Conduit Openings:½" NPT conduit

Description :Microprocessor-controlled and menu-driven controller that operates the sensor

Dimensions:½ DIN - 144 x 144 x 192 mm (5.7 x 5.7 x 7.6 in.)

Display:3.5-inch TFT colour display with capacitive touchpad

Enclosure Rating:UL50E type 4X, IEC/EN 60529–IP 66, NEMA 250 type 4X
Metal enclosure with a corrosion-resistant finish

Indoor/Outdoor:Outdoor installation in direct sunlight or UV radiation requires UV protection screen and/or sunroof

Installation category:Category II

Material Enclosures:Polycarbonate, aluminum (powder coated), stainless steel

Measurements:Two device digital SC connectors

Mounting:Wall, Pole, or Panel Mounting

Network connectivity:LAN: Two Ethernet connectors (10/100 Mbps)
Cellular: External 4G
Wi-Fi

Operating Temperature Range:-20 to 60 °C (-4 to 140 °F) (8 W (AC)/9 W (DC) sensor load)
-20 to 45 °C (-4 to 113 °F) (28 W (AC)/20 W (DC) sensor load)
Linear derating between 45 and 60 °C (-1.33 W/°C)

Outputs:5x mA Output

Pollution Degree:4

Power requirements (Voltage):100 - 240 VAC ±10%, 50/60 Hz; 1 A

Power supply:Without power cord

Protection Class:I, connected to protective earth

Relays:Two relays (SPDT);
Wire gauge: 0.75 to 1.5 mm² (18 to 16 AWG)

Maximum switching voltage: 100 - 240 VAC
Maximum switching current: 5 A Resistive/1 A Pilot Duty
Maximum switching power: 1200 VA Resistive/360 VA Pilot Duty

Sensor Input #1:Analog Conductivity

Sensor Input #2:Analog Conductivity

Software Available:Non-Claros + Embedded Prognosys

Storage conditions:-20 to 70 °C, 0 - 95% relative humidity, non-condensing

USB Port:Used for data download and software upload. The controller records approximately 20,000 data points for each connected sensor.

Features

Easy Adoption

The familiar experience of a modern touchscreen, the ability to use your current Hach sensors, and the same footprint as the SC200, make installation and integration of the SC4500 Controller seamless.

No Time for Downtime

The SC4500's built-in predictive diagnostic software ensures measurement confidence and reduces the risk of unexpected equipment downtime by enabling proactive maintenance planning via MSM, including step-by-step instructions.

The Connectivity Options You Need

The Controller is Smart Monitoring enabled and provides local communication to SCADA or a PLC. From analog and advanced digital protocols to Wi-Fi, cellular or LAN, the SC4500 gives you the flexibility to adapt in a rapidly changing world.